Review



liquid waveguide capillary cell, pathlength  (World Precision Instruments)


Bioz Verified Symbol World Precision Instruments is a verified supplier
Bioz Manufacturer Symbol World Precision Instruments manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    World Precision Instruments liquid waveguide capillary cell, pathlength
    Liquid Waveguide Capillary Cell, Pathlength, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 252 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/custom%40lwcc-3500%4010%2E1016%2Fj%2Eatmosres%2E2026%2E109199
    Average 95 stars, based on 252 article reviews
    liquid waveguide capillary cell, pathlength - by Bioz Stars, 2026-09
    95/100 stars

    Images

    Related Articles

    Spectrophotometry:

    Article Title: Device and method for assessing oxidative potential of ambient particulate matter
    Article Snippet: .. In the third (measurement) step, the diluted mixture in MV1 is withdrawn from the vial and pushed through a liquid waveguide capillary cell (LWCC-3100; World Precision Instruments, Inc., Sarasota, FL), where the absorbance at 265 nm and 600 nm (background) is measured by the spectrophotometer and is recorded by Ocean Optics SpectraSuite software. ..

    Article Title: Supplemental Information for Chloramines as an important photochemical source of chlorine atoms in the urban atmosphere
    Article Snippet: .. A liquid waveguide capillary cell (LWCC, World Precision Instruments) with an optical path of 50 cm coupled to a UV−vis spectrophotometer (USB2000+, Ocean Op cs) was used to measure the light absorbance of the chloramine solutions. ..

    Article Title: Measurement report: Oxidation potential of water-soluble aerosol components in the south and north of Beijing
    Article Snippet: .. Finally, the concentration of WSOC was measured with a total organic carbon–total nitrogen analyzer (TOC-L, Shimadzu, Japan; (Ho et al., 2015)), and the light absorption of WSOC was measured by a UV–Vis spectrophotometer (300–700 nm; Ocean Optics, USA) equipped with a liquid waveguide capillary cell (LWCC-3100, World Precision Instruments, Sarasota, FL, USA; (Yuan et al., 2020)). ..

    Article Title: Online water-soluble iron speciation in ambient aerosols under cloud-water-relevant and neutral conditions
    Article Snippet: .. A previous reduction of the present dissolved Fe(III) further enables the determination of the total https://doi.org/10.5194/ar-4-81-2026 Aerosol Res., 4, 81–101, 2026 soluble-iron fraction. total ws-Fe= ws-Fe(II)+ws-Fe(III) (4) This FIA system includes two peristaltic pumps (ISMATEC, IPS 8), a common six-port valve used in HPLC systems (BESTA, Germany) with an injection loop, a twoway switching pinch valve (ASCO S306.02-Z530A), a 2 m reduction coil with an inner diameter of 0.5 mm and a volume of 0.4 mL, an 8 m reaction coil with an inner diameter of 0.5 mm and a volume of 1.6 mL, a UV–Vis light source (DH2000-BAL, Ocean Optics, Germany), a USB Spectrophotometer (USB4000-XR1-ES, Ocean Optics, Germany), and a liquid waveguide capillary cell (LWCC 3100, World Precision Instruments, Friedberg, Germany, 100 cm pathlength, 250 μL internal volume, 0.5 mm inner diameter) (see Fig. 2). ..

    Software:

    Article Title: Device and method for assessing oxidative potential of ambient particulate matter
    Article Snippet: .. In the third (measurement) step, the diluted mixture in MV1 is withdrawn from the vial and pushed through a liquid waveguide capillary cell (LWCC-3100; World Precision Instruments, Inc., Sarasota, FL), where the absorbance at 265 nm and 600 nm (background) is measured by the spectrophotometer and is recorded by Ocean Optics SpectraSuite software. ..

    Concentration Assay:

    Article Title: Measurement report: Oxidation potential of water-soluble aerosol components in the south and north of Beijing
    Article Snippet: .. Finally, the concentration of WSOC was measured with a total organic carbon–total nitrogen analyzer (TOC-L, Shimadzu, Japan; (Ho et al., 2015)), and the light absorption of WSOC was measured by a UV–Vis spectrophotometer (300–700 nm; Ocean Optics, USA) equipped with a liquid waveguide capillary cell (LWCC-3100, World Precision Instruments, Sarasota, FL, USA; (Yuan et al., 2020)). ..

    Aerosol:

    Article Title: Online water-soluble iron speciation in ambient aerosols under cloud-water-relevant and neutral conditions
    Article Snippet: .. A previous reduction of the present dissolved Fe(III) further enables the determination of the total https://doi.org/10.5194/ar-4-81-2026 Aerosol Res., 4, 81–101, 2026 soluble-iron fraction. total ws-Fe= ws-Fe(II)+ws-Fe(III) (4) This FIA system includes two peristaltic pumps (ISMATEC, IPS 8), a common six-port valve used in HPLC systems (BESTA, Germany) with an injection loop, a twoway switching pinch valve (ASCO S306.02-Z530A), a 2 m reduction coil with an inner diameter of 0.5 mm and a volume of 0.4 mL, an 8 m reaction coil with an inner diameter of 0.5 mm and a volume of 1.6 mL, a UV–Vis light source (DH2000-BAL, Ocean Optics, Germany), a USB Spectrophotometer (USB4000-XR1-ES, Ocean Optics, Germany), and a liquid waveguide capillary cell (LWCC 3100, World Precision Instruments, Friedberg, Germany, 100 cm pathlength, 250 μL internal volume, 0.5 mm inner diameter) (see Fig. 2). ..

    High Performance Liquid Chromatography:

    Article Title: Online water-soluble iron speciation in ambient aerosols under cloud-water-relevant and neutral conditions
    Article Snippet: .. A previous reduction of the present dissolved Fe(III) further enables the determination of the total https://doi.org/10.5194/ar-4-81-2026 Aerosol Res., 4, 81–101, 2026 soluble-iron fraction. total ws-Fe= ws-Fe(II)+ws-Fe(III) (4) This FIA system includes two peristaltic pumps (ISMATEC, IPS 8), a common six-port valve used in HPLC systems (BESTA, Germany) with an injection loop, a twoway switching pinch valve (ASCO S306.02-Z530A), a 2 m reduction coil with an inner diameter of 0.5 mm and a volume of 0.4 mL, an 8 m reaction coil with an inner diameter of 0.5 mm and a volume of 1.6 mL, a UV–Vis light source (DH2000-BAL, Ocean Optics, Germany), a USB Spectrophotometer (USB4000-XR1-ES, Ocean Optics, Germany), and a liquid waveguide capillary cell (LWCC 3100, World Precision Instruments, Friedberg, Germany, 100 cm pathlength, 250 μL internal volume, 0.5 mm inner diameter) (see Fig. 2). ..

    Injection:

    Article Title: Online water-soluble iron speciation in ambient aerosols under cloud-water-relevant and neutral conditions
    Article Snippet: .. A previous reduction of the present dissolved Fe(III) further enables the determination of the total https://doi.org/10.5194/ar-4-81-2026 Aerosol Res., 4, 81–101, 2026 soluble-iron fraction. total ws-Fe= ws-Fe(II)+ws-Fe(III) (4) This FIA system includes two peristaltic pumps (ISMATEC, IPS 8), a common six-port valve used in HPLC systems (BESTA, Germany) with an injection loop, a twoway switching pinch valve (ASCO S306.02-Z530A), a 2 m reduction coil with an inner diameter of 0.5 mm and a volume of 0.4 mL, an 8 m reaction coil with an inner diameter of 0.5 mm and a volume of 1.6 mL, a UV–Vis light source (DH2000-BAL, Ocean Optics, Germany), a USB Spectrophotometer (USB4000-XR1-ES, Ocean Optics, Germany), and a liquid waveguide capillary cell (LWCC 3100, World Precision Instruments, Friedberg, Germany, 100 cm pathlength, 250 μL internal volume, 0.5 mm inner diameter) (see Fig. 2). ..



    Similar Products

    95
    World Precision Instruments liquid waveguide capillary cell, pathlength
    Liquid Waveguide Capillary Cell, Pathlength, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/custom%40lwcc-3500%4010%2E1016%2Fj%2Eatmosres%2E2026%2E109199
    Average 95 stars, based on 1 article reviews
    liquid waveguide capillary cell, pathlength - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    World Precision Instruments path length liquid waveguide capillary cell
    Path Length Liquid Waveguide Capillary Cell, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/10__1029_slash_2025jd045861-81-24-31
    Average 95 stars, based on 1 article reviews
    path length liquid waveguide capillary cell - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    World Precision Instruments liquid waveguide capillary cell
    Liquid Waveguide Capillary Cell, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/10__5194_slash_ar___4___81___2026-113-111-117
    Average 95 stars, based on 1 article reviews
    liquid waveguide capillary cell - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    World Precision Instruments liquid waveguide capillary cell uv vis spectrometer
    Liquid Waveguide Capillary Cell Uv Vis Spectrometer, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/10__5194_slash_acp___25___12037___2025-41-18-25
    Average 95 stars, based on 1 article reviews
    liquid waveguide capillary cell uv vis spectrometer - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    World Precision Instruments long pathlength lwcc
    Long Pathlength Lwcc, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/pm40885135-64-7-12
    Average 95 stars, based on 1 article reviews
    long pathlength lwcc - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    World Precision Instruments long liquid waveguide capillary cell
    Long Liquid Waveguide Capillary Cell, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+waveguide+capillary+cell/Liquid+Waveguide+Capillary+Cell%2C+pathlength/10__5194_slash_acp___25___8493___2025-59-41-47
    Average 95 stars, based on 1 article reviews
    long liquid waveguide capillary cell - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    Image Search Results